Panasonic P2 serial
Supported models
- AG-HPX300
- AG-HPX500
- AJ-HPX2700
- AJ-HPX3100
- Generic : will assume all features are available
note
All AJ-HPX cameras with the Hirose 10p connector are supported. Simply select Generic
model. Depending on the model (if not specificaly listed), some features may not be available or not working properly.
Wiring
Required cable CY-CBL-6P-PAN-10P.
Compatible Cyanview device
- CI0 for local (LAN)
- RIO for remote control (internet)
Controls
Control | AG-HPX300 | AG-HPX500 | AJ-HPX2700 | AJ-HPX3100 | Generic |
---|---|---|---|---|---|
OSD | ✔ | ✔ | ✔ | ✔ | ✔ |
Gain (M / R / B) | ✔ | ✔ | ✔ | ✔ | ✔ |
Pedestal (M / R / B) | ✔ | ✔ | ✔ | ✔ | ✔ |
Gamma (M / R / B) | ✔ | ✔ | ✔ | ||
Black gamma | ✔ | ✔ | ✔ | ||
Saturation | ✔ | ✔ | ✔ | ||
Whiteclip | ✔ | ✔ | ✔ | ||
Knee | ✔ | ✔ | ✔ | ||
Matrix | ✔ | ✔ | ✔ | ||
Detail | ✔ | ✔ | ✔ | ||
ND filters | RO | ✔ | |||
AWB | ✔ | ✔ | ✔ | ✔ | ✔ |
Iris | ✔ | ✔ | ✔ | ✔ | ✔ |
Shutter | ✔ | ✔ | ✔ | ✔ | ✔ |
Setup
On your RCP/RIO:
- Setup a new camera via the RCP Configuration UI:
- Select Panasonic brand
- Select P2 model
- Select your CI0/RIO port on which the camera is plugged
And once the camera is correctly controlled by the RCP, it should look like that: