Skip to main content

Diagnostic Report

Use Admin → Diagnostics to check device reachability, review configuration findings or record a fault for support. Open the web interface of the Cyanview unit that controls the affected equipment and scroll down to Diagnostics. If a RIO connects directly to the camera, start on that RIO. If a camera connects through a CI0 to an RCP, start on the RCP.

What you need to find outUse
Can the RCP or RIO ping a camera or other device? Does the device drop off the network?Check a device
Are there issues in the unit’s network configuration or system state, such as duplicate IP addresses or incorrect subnet masks?Test configuration
Can I capture startup across the whole configuration to investigate camera connection or control issues?Full test, off air
What happens when I reproduce a fault or wait for it to recur?Manual capture
What is the gateway reporting while the system is running?Logs
How do I collect detailed gateway traces requested by support?Gateway version and debug traces, off air
What should I send to Cyanview support?Send the package to Cyanview support

Gateway version and debug traces​

Version shows the running gateway build. Use production for normal operation. Use the debug build when you want more debug information or plan to send a full test capture to Cyanview support.

warning

Switching either way restarts the gateway. Cameras, panels and other devices can disconnect for about a minute. Switch builds off air.

  1. Select Switch to the debug version, then Switch now. Wait for the page to reconnect and check that Version shows debug.
  2. Run a Full test to capture connection startup, or use Manual capture to record the issue as it happens. Save the package.
  3. Select Switch back to the production version, then Switch now. Verify that Version shows production and that device control has returned. A unit reboot also starts the production build.

Check a device​

Use this check to watch one IPv4 address from the Cyanview unit. It leaves the configuration intact.

Check a device controls. Callout 1 points to IP address and callout 2 points to Start.

  1. Enter the device's IP address. To test TCP connections as well, enter the ports listed in the device's integration instructions, separated by commas.
  2. Select Start. Review the findings and Changes (most recent first). Leave the check running until you see the symptom, then select Stop.
ResultWhat to check
No route or an unexpected outgoing interfaceCheck the unit's address, subnet mask and route to the device.
More than one MAC address answers ARP for the same local IPCheck for two devices configured with that address. ARP applies to devices on the local link.
No answer to ping, but the expected TCP port is openThe device can accept a TCP connection. It may ignore ICMP ping. Continue checking the integration if control still fails.
Ping works, but the expected TCP port is refusedConfirm the correct port and check that the device's control service is enabled. If the port times out, check for filtering or a lost connection.

Example. An IP camera loses control intermittently. Watch its address and the TCP port used for control. When the fault occurs, check whether the device stopped answering altogether, another MAC appeared for its address, or only the control port stopped responding.

Test configuration​

Select Run test for a report on the unit's network and system state. The test checks local IP settings and routes, looks for address conflicts involving the unit or configured devices on its local network, and looks for kernel warnings and errors. It leaves the configuration intact.

Review the warnings and errors first. Read the details under each finding for the affected interface, address or device and any suggested next step. If a check could not run, treat that part of the report as incomplete.

Example. After moving the unit to a different subnet, the report flags an IP setting. Compare the reported address, subnet mask and route with the network plan. Correct the setting in the unit's configuration, then run the test again. If it reports No problem found and the fault persists, use Check a device for an individual IP or Manual capture to record the symptom.

Full test​

warning

Run the full test off air. It briefly disconnects configured cameras, colour correctors, routers, switchers and control panels while the gateway re-establishes their connections.

Use Full test to capture how the gateway establishes control connections across the whole configuration. The gateway starts the configured device connections again from scratch and records network traffic, MQTT messages, logs and configuration. The report summarizes configuration and runtime findings. The package gives Cyanview support the startup evidence to investigate why a camera fails to connect or respond to control.

Full test controls. Callout 1 points to the 180-second observation field and callout 2 points to Run full test.

  1. Leave Observe for at 180 seconds for the first run. The timer starts after the device connections restart. Some devices take about two minutes to give up on a failed connection.
  2. Select Run full test. Wait for the observation period and package build to finish.
  3. Review the findings and any notes beneath the report. If there are unresolved findings or support requested the test, select Export report package and save the archive. If the report could not be built, export the package if available. Send the saved package to Cyanview support.
  4. After verifying the download, use Delete to free the unit's memory. If there is no package and the result shows Clear, use it to reset the test. Manual capture is unavailable while the full test runs or its result is kept.

Example. Several devices fail to come online after setup. Run the full test during a maintenance window to capture their connection attempts, then compare which devices recovered and which still show a fault.

Manual capture​

Use Manual capture when the fault happens during a specific action or after the system has been running for a while. The capture records network traffic seen by the unit, MQTT messages, gateway logs and system state. Capture data is encrypted as it is recorded for Cyanview support.

Choose where to record​

  • Unit memory suits a short, repeatable test. The default budget is 50 MB and the limit is 100 MB. Download the package before restarting the unit.
  • USB drive suits a longer capture. Use a FAT32 or ext4 drive. If it does not appear, select Look for USB drives. Select the drive and wait for it to mount. With the size field blank, the unit chooses a budget based on available space, up to 3.5 GB. Format and use it erases the selected drive.
  • Stop after minutes is optional. For an intermittent fault, leave it blank and stop soon after the fault. As the recording fills its size budget, it drops the oldest rolling data to keep recording.

Choose what to record​

  • All traffic (recommended) is the default. It excludes routine traffic such as web access to the unit and the cloud tunnel. MQTT messages are recorded separately.
  • One device limits the network packet capture to the specified IP address and optional port. Use it when the target device is known and traffic from other devices would fill the capture too quickly.
  • Advanced (tcpdump filter) lets you enter a packet filter. Use the filter supplied by support when they ask for a specific capture.

Record and save the package​

  1. Select Start capture before reproducing the problem. Recording… shows the elapsed time and the amount recorded against the size limit. When the fault occurs, note the time and time zone, the affected device, and the action you took.

    Manual capture in progress, showing the elapsed time, recorded size, and Stop and build package button.

  2. Select Stop and build package as soon as you have reproduced the fault. Wait for The package is ready. Review any recording warnings and mention them when sending the package.

  3. For unit memory, select Download and verify that the .tar file is saved on your computer. Keep that file to send to Cyanview support. Select Delete on the unit to clear its copy. You must clear it before starting another capture.

    A finished package in unit memory, with Download and Delete buttons.

  4. For USB, download the package from Captures in this session or retrieve it directly from the drive. That list also provides Rename and Delete controls for saved USB packages. Wait until the page confirms that the package was saved, then select Eject before unplugging the drive.

Example. After several hours of operation, an iris command sometimes stops reaching a camera. Start a USB capture with All traffic (recommended). When it happens, note the time, the camera and the command, then stop the capture promptly so the recording still includes the lead-up to the failure.

Logs​

Open Admin → Logs, directly below Diagnostics, to see what the gateway reports while the system is running. Select Show if the log is hidden. Each row shows the level, time, gateway component, and message.

  • info, warning, and error are enabled by default. Select verbose or debug to see more detail in new messages. These buttons control which messages reach the live view.
  • Select Clear to empty the on-screen list before reproducing a fault. The unit keeps its saved log files. Select Hide to close the live view.
  • Select Download to save the unit's recent gateway logs as CyanView_log.zip. A manual capture or full test package already includes gateway logs, so you can skip the separate log download.

Example. If a camera repeatedly drops offline, watch Logs as it disconnects and reconnects. Note the time and look for connection warnings or repeated attempts around that time. Enable verbose and debug if the default levels give too little detail. The debug build can produce additional traces for these levels. Switch builds off air because the gateway restarts.

Send the package to Cyanview support​

Attach the exported .tar file to your existing support ticket or email it to support@cyanview.com.

For camera connection or control problems at startup, send a Full test package. Take the unit off air and switch to the debug build before running the test. For a fault you can reproduce during operation, send a Manual capture that covers the time of the fault.

Include the following with the package.

  • The Cyanview unit name or serial number and the version shown under Diagnostics.
  • The affected device or camera, what you expected to happen, and what happened instead.
  • The steps you took and when you observed the problem, including the time zone.
  • Any relevant on-screen findings or capture warnings.